Windtrap Telephone: 0845 567 70 80

WindyBoy Protection Box 600 with Load Resistor

WindyBoy Protection Box 600 with Load ResistorMain Image

Rectifier and overvoltage protection

by CCL components ltd

£1,278.19 inc VAT


  • how it works
  • technical spec
  • WindyBoy Protection Box 600 with Load Resistor

    Rectifier and overvoltage protection – the Windy Boy Protection Box from SMA is multitalented: The WBP-Box limits excessive voltage and power from the generator and redirects it to a load resistor without limiting the power of your small wind energy plant. This reliably protects the inverter from high input voltages and ensures trouble-free operation.
     
    The Windy Boy Protection Box is equipped with a three-phase rectifier. It is delivered as a turnkey unit and can be used with nearly all types of generators from various manufacturers and with different power classes. This makes the Windy Boy Protection Box the optimal solution for wind power plants, but also provides the perfect link between permanent magnet
    generators and the inverter.

    Features:
    ·         Highly dynamic overvoltage protection
    ·         Yield protection: Grid feeding even with excessive input voltage
    ·         Optimal start-up performance of the wind turbine
    ·         Three-phase generator connection
    ·         High efficiency of the rectifier
    ·         Easy installation
    ·         Available in three different voltage ranges: 400, 500, and 600 V



    WindyBoy Protection Box 400 suitable for WB1100, WB1200, WB1700

    WindyBoy Protection Box 500 suitable for WB3300, WB3800

    WindyBoy Protection Box 600 suitable for WB2500, WB2800i, WB3000, WB5000A, WB6000A 


    Rectifier and overvoltage protection

    Can be used with nearly all types of generators from various manufacturers and with different power classes
    • General Information
    • Suitable for WB 2500, WM 2800i, WB 3000, WB5000A, WB 6000A
    • Integrated rectifier
    • dimensions (w/h/d)mm = 280 x 220 x 130
    • weight = 5kg
    • generator connection
    • number = 1 x 3 phase
    • AC voltage = 3 x 0 ... 500VAC
    • AC current = 3 x 0 ... 11.5 AAC
    • Generator frequency = 0...400 Hz
    • Related Power = 2....6 KW
    • Windy Boy connection
    • Number = 3
    • Voltage limitation = 600 VDC
    • Total output = 6kw
    • Load Resistor Connection
    • Number = 1
    • Nominal Voltage = 600 VDC
    • Continuous Power = 6kw
    • Efficiency
    • Max efficiency = >99.95%
    • Losses at continuous power = 30W
    • Ambient conditions
    • Ambient temperature = -25C......+60C
    • Enclose rating (DIN EN 60529) = IP54
    • Accessories
    • Load resistor = optional

WindyBoy Protection Box 600 with Load Resistor WindyBoy Protection Box 600 with Load Resistor